RUiXU RX-LFP48100-H 19″ Server Rack 3U Battery UL1973 Certified Self-Heating

$1,099.00

-

SKU: RX-LFP48100-H Categories: , Tag:

Description

The self-heating 48V server rack battery is designed for usage in cold weather! Can safely charge at temperatures as low as -20°C (-4°F) by a standard charger or solar charger. The heated pads draw power from the charger itself.

 

Support up to 32 units in parallel, scale from 5 kWh to 160 kWh configuration without external controller.

 

3U (133mm) standard height design

 

Use DIP address to set the RS485 baud rate and inverter protocol choosing

 

Comes with battery interconnection Amphenol connectors.


 

 

Details

Rated voltage: 51.2V
Max. voltage range: 44.8~57.6V, Shipping voltage>51.2V
Charge voltage: 56.0V
Float charge voltage: 54.6V
Low voltage cut-off: 44.8V
Nominal energy: 5.12KWh
Usable energy: 4.92kWh
Nominal capacity: 100Ah
Dimensions: 482*133.5*460mm (18.9*5.2*18.1 inch)
Weight: ~50kg (110lbs)
Standard charge current: ≤50A
Max. charge current: 70A
Standard discharge current: ≤50A
Max. discharge current: 100A (initial temp. ≤35℃ [95°F])
Peak discharge current: 101~119A@5mins | 120~150A@5S
Communication: RS485 /CAN
Max parallel number: 32pcs
Operation temperature1 Charge: 0~50℃ (32~122°F)
Discharge: -20~50℃ (-4~122°F)
Storage temperature: 0℃<T<30℃ (32°F<T<86°F)<6 months | -10℃<T<45℃ (14°F<T<113°F)<3 months
Recommended environment: 15~35℃ (59~95°F), 5~75%RH
Start heating: When the Minimum Cell temperature is between -25°C and 5°C (-13°F and 41°F), the battery is connected to the charger or inverter and the charging current is ≥ 0.05C*N, start heating.
End heating: When the Minimum Cell temperature is above 12°C (53.6°F), end heating.

 

(1) The optimum operating temperature range is from 15°C to 30°C (15°F to 86°F). Frequent exposure to the harsh
temperatures may worsen the performance of the battery pack and cycle life.

 

 

Modular

Support up to 32 units in parallel, scale from 5 kWh to 160 kWh configuration without external controller.

 

 

Inverter Protocol Choosing

Use DIP address to set the RS485 baud rate and inverter protocol choosing

 

 

Communications

Canbus: Victron, SMA, Studer Innotec, Sofar, Solark, Solis, Goodwe, Deye, Growatt, SAJ, LUXPOWER, Megarevo, INVT, Sermatec, TBB, MUST, Sunsynk, Schneider
RS485: MPP, Voltronic, RCT, Alpha outback

 

 

Standard Included

(1) RUiXU 48V Server Rack battery (RX-LFP48100-H)
(1) RS485 Communication Cable 
(1) Ground Cable 
(1) Set of Parallel 4AWG Cables  per battery


 

SKU:

RX-LFP48100-H

Additional information

Weight110 lbs
Dimensions24 × 21 × 13 in