MidNite Solar Lightning and Surge Arrestor 300DC
$146.38
-
- Description
- Downloads
- Additional information
Description
MidNite Solar Surge Protective Device (MNSPD): Engineered for both indoor and outdoor use, our Type 1 SPD safeguards AC and DC systems, including transformer and transformer-less inverters. It complements GFP protection circuits and defends service panels, load centers, or directly connected electronic devices. Available in three voltage options (MNSPD-300AC, MNSPD-300DC and MNSPD-600) for tailored protection. Proper installation is crucial for maximum effectiveness.
Protect Your Electronics: Our MidNite Solar SPDs reduce clamping voltage to a safe level, preventing electronic damage. Refer to our selection chart (pg.2 in installation manual) to choose the right SPD for your system. Ensure the SPD’s operating voltage exceeds the system voltage to avoid overvoltage issues, which can lead to performance degradation or failure. Make the right choice for long-lasting protection and peace of mind.
SPECIFICATIONS
Nominal Voltage:
0 to 300 VDC
MCOV VRMS @1mA:
470V (423-517)
ClampV @ 100A Current 8/20µs:
775V
I peak (8/20µs) (Current):
100kA (Full Device)
50kA (Each Section)
Energy Absorption:
3130 J (Full Device)
1560 J (Each Section)
Suggested Placement:
120/240VAC circuits
Offgrid PV combiners
Charge controller inputs up to 300VDC
Diagnostics:
LED indicators when voltage is present between DC+ and DC-
Operating Temperature Range:
-40°C to +85°C (-40°F to +185°F)
Nominal Discharge Current INA:
20kA
Thermal Disconnector:
Internal Fuse
Response Time:
<15n sec.
Additional information
| Weight | 1 lbs |
|---|